The increase in usedPercent, in points, of one provider window across
a step, or Option.none() when the step is not measured in that window.
The reading before is the latest one at or before the step's start; the
reading after is the earliest one at or after its end. "Before" and
"after" compare monotonic stamps from the step's boot, never the wall
clock; ties are broken by ledger seq, the later-ingested reading winning.
Both readings must be usable, read strictly (owner ruling 2026-11-16):
the reading before at most freshnessMillis older than the start, the
reading after at most freshnessMillis newer than the end, both bounds
inclusive. Fewer steps are measured, so more fall back to
initialEstimate. Both readings must also have a reset time, and the
two must be equal (no reset in between).
A fall in usage gives 0. A measured 0 stays 0 here; only the estimate
is floored.
The increase in
usedPercent, in points, of one provider window across a step, orOption.none()when the step is not measured in that window.The reading before is the latest one at or before the step's start; the reading after is the earliest one at or after its end. "Before" and "after" compare monotonic stamps from the step's boot, never the wall clock; ties are broken by ledger seq, the later-ingested reading winning.
Both readings must be usable, read strictly (owner ruling 2026-11-16): the reading before at most
freshnessMillisolder than the start, the reading after at mostfreshnessMillisnewer than the end, both bounds inclusive. Fewer steps are measured, so more fall back toinitialEstimate. Both readings must also have a reset time, and the two must be equal (no reset in between).A fall in usage gives 0. A measured 0 stays 0 here; only the estimate is floored.